DPF Monitor Mini
Technical specification
| Operating voltage | 6-19V (32V MAX) |
| Current draw in operation | ~40mA |
| Current draw in sleep mode | <8mA @ 12.5V 25°C |
| Operating temperature | -30°C to +85°C |
| Supported CAN standard | UDS |
| Display | AMOLED 460x280px |
| Device dimensions | 43.5mm x 28.5mm x 11mm (W x H x D) |
| Housing material | ASA-CF (display), PETG-CF (OBD2 connector) |
| Cable length | 1.40m |
User manual
Always connect the device in the car for the first time with the engine running.
Touch gestures
The device is operated entirely with gestures on the touchscreen.
Swipe left / right
Changes the main screen page (7 pages).
Swipe down
Opens the menu – works from any page.
Swipe up
Page 6 – shows max / min values.
Page 7 – resets the maximum values.
Tap the screen
Switches between light (day) and dark mode.
Only works when Auto brightness is turned off.
Press and hold the screen
Switches the main screen theme (theme 1 / theme 2).
Main screen pages
The main screen has 7 pages – choose the one that suits you best.
1 Overview with clock
- CenterClock
- Top leftTime since engine start
- Top rightCurrent oil temperature
- Bottom leftDPF load in %, based on the calculated soot mass
- Bottom rightDistance since last regeneration
- BottomDPF status icon
2 DPF and fluid temperatures
- Left sideDPF load and distance since last regeneration
- Right – topDPF status icon
- Right – bottomOil temperature red icon and coolant temperature blue icon
3 Soot mass
- Left sideDPF load and distance since last regeneration
- Right – topCalculated and measured soot mass
- Above calculatedSoot accumulation rate in mg/km how many mg of calculated soot is added per kilometre driven
- Right – bottomDifferential pressure
4 Filter temperatures
- Left sideDPF load and distance since last regeneration
- Right – topTemperature before and after the DPF
- Right – bottomDifferential pressure
5 Key DPF parameters
All parameters are labelled directly on the device screen.
With Switch page to regen enabled, the device switches to this page automatically for the duration of a regeneration.
6 Parameters with max / min view
All parameters are labelled directly on the device screen. The device records a maximum and a minimum value for each of them – you switch between them by swiping up.
- 1st swipeMaximum values
- 2nd swipeMinimum values
- 3rd swipeBack to live values
Maximum and minimum value view
7 Differential Pressure Test
- Main areaDifferential pressure reading
- In redMaximum values
- Bottom leftCurrent DPF load in %
Swipe up to reset the maximum values. The Clear max after regen option does this automatically after every regeneration.
Settings
The options are grouped by topic – each one is described below.
Performance and data logging
Enables fast mode – the CAN bus is polled at a higher rate.
Logs data to the microSD card once per second into a CSV file. A new file is created e.g. after every DPF regeneration. Details in tab 9 – SD card.
Information display
After the engine is switched off, the device shows the trip statistics for 10 seconds before going to sleep.
How to read the statistics
- Red shows the maximum recorded values.
- Blue shows the minimum recorded values.
- For the calculated and measured soot mass, white shows the difference since engine start. For example, a value of +1.21 means the soot mass increased by 1.21 grams between starting the engine and the end of the trip. A value of -0.50 means the soot mass decreased by 0.50 grams.
Signals passive regeneration on the main screen – the temperatures or the DPF icon turn orange. Detected from a drop in the measured soot mass.
During a DPF regeneration the screen switches automatically to page 5 – the one with the key DPF parameters.
After a regeneration finishes, the maximum values on page 7 (Differential Pressure Test) are reset automatically.
Audible signals
Audible signal when a DPF regeneration starts and finishes.
Signal volume: HIGH – loud, LOW – quiet.
Screen brightness
Switches between day and night mode automatically. With this option off, you switch modes manually by tapping the screen.
Smooth transition between day and night brightness instead of a step change. Active only with Auto brightness turned on.
Screen brightness level in day mode.
Screen brightness level in night mode.
Setting the clock
- Swipe up or down over the hours field to change the value.
- Repeat the same over the minutes field.
- Press the SET button to save.
DTC – fault codes
Fault codes are read automatically when you open the DTC page.
Reads the DTCs (Diagnostic Trouble Codes) stored in the ECU memory. Use it to refresh the list manually.
Clears all DTCs stored in the ECU memory.
Regeneration history
- CapacityThe last 10 DPF regenerations once full, the oldest entry is overwritten
- OrderThe first record is always the most recent regeneration, the following ones are older
- BrowsingSwipe left or right on the right-hand side of the screen
- ClearingPress and hold the History button for 2 seconds
0-100 km/h acceleration test
- Top rightCurrent measurement result
- BelowThe last three results – the best one is marked green
- Reset resultsPress and hold RESET to clear the last three results
On-screen statuses
- READYReady to start a measurement
- STOPWaiting for the car to come to a stop
- RESETWaiting for the reset button to be pressed to start a new measurement
Engine data readout (Advanced)
Reading the parameters
Data available on 4 pages:
- Page 1Boost pressure, fuel rail pressure, MAF actual and specified values
- Page 2Injector corrections of cylinders 1-6, mean injection quantity Mean Inj Q (mg/str), EGR closing, ΔP sensor offset
- Page 3Exhaust gas temperatures 1-4
- Page 4Post Injection 1/2/3 – post injection quantity (mg/str) or control duration when the title shows [ms] – and Lambda during an active regeneration post injection 2 or 3 rises
A value the ECU of a given engine does not provide is greyed out and shows 0.
- EnterThe Advanced button in the menu
- Page changeSwipe up or down 4 pages
- ExitSwipe left to right
Graph view
Available graphs: boost pressure, fuel pressure and MAF – actual and specified values.
- Press and hold the Advanced button for 2 seconds.
- Select the graph you want to view.
List of available graphs.
Data logging to a microSD card
The device can log driving data to a microSD card – one row per second in a CSV file. The logs let you analyse filter loading and regenerations in detail later.
Starting the logging
- Insert a microSD card formatted as FAT32 or exFAT. The card is hot swappable – no need to disconnect the device.
- In Settings turn on SD Card Save. The switch is only active with a card inserted.
- A blinking green dot at the top edge of the screen means logging is active.
- Rate1 row every second data is physically written to the card every 5 seconds
- Sizeabout 250 kB per hour of driving even a small card lasts a very long time
- File namesdpf_log_0.csv, dpf_log_1.csv, … each new file gets a number one higher than the highest on the card, up to dpf_log_999
When is a new file created?
- Card insertedEvery time the card is inserted, logging starts in a new file
- Device startAfter the device starts or restarts e.g. after plugging it into the OBD-II port again
- End of regenerationAfter every DPF regeneration ends so one file covers one filter loading cycle – from regeneration to regeneration
After switching the engine off and on again, or turning SD Card Save off and on, data is appended to the same file.
CSV file contents
The first row holds the column names, the separator is a comma and the decimal separator is a dot. Every following row is one second of driving.
| DPF_in | DPF inlet temperature, °C |
| DPF_out | DPF outlet temperature, °C |
| Diff_press | differential pressure ΔP, hPa |
| Last_regen_km | distance since last regeneration, km |
| Last_regen_min | time since last regeneration, min |
| Oil_temp | oil temperature, °C |
| Soot_calc | calculated soot mass, g |
| Soot_meas | measured soot mass, g |
| Coolant | coolant temperature, °C |
| Batt | battery voltage, V |
| Engine_time | engine run time since start, min |
| Intake | intake air temperature, °C |
| Engine_speed | engine speed, RPM |
| Vehicle_speed | vehicle speed, km/h |
| Post_Inj2 | post injection 2 (raw ECU value) |
| Post_Inj3 | post injection 3 (raw ECU value) |
| Oil_Ash | oil ash, g or l (engine dependent) |
Parameters not supported by a given engine are logged as 0.
How to view the logs?
The most convenient way is to view the log as graphs in an online log viewer – just load the CSV file in your browser and pick the parameters to compare.
- Onlinedatazap.me, csvplot.com graphs of many parameters on a common time axis
- OfflineMegaLogViewer, Excel, LibreOffice Calc if your Excel uses a decimal comma, open the file via Data → From Text/CSV and set the comma as separator and the dot as decimal separator
- Worth comparingGrowth of Soot_calc and Soot_meas, Diff_press vs Engine_speed, and DPF_in / DPF_out temperatures during regeneration Post_Inj2 / Post_Inj3 above 0 means active post injection, i.e. regeneration
Removing the card and write errors
It is safest to remove the card with the engine off (the device is asleep and the file is closed) or after turning SD Card Save off. Removing the card while logging may lose the last few seconds of data.
- Write errorIf a write error occurs, the SD Card Save switch turns grey and logging is disabled. To restore it, reset the device – unplug it from the OBD-II port and plug it in again
Download the manual
The user manual as a PDF – for printing or reading on your phone.
- User Manual – English TDI common-rail engines (UDS) • SW 1.9.7.5 • PDF • 6.3 MB
- Instrukcja obsługi – Polish TDI common-rail engines (UDS) • SW 1.9.7.5 • PDF • 6.3 MB
- User Manual BLS / BXE / BMN – English 1.9 / 2.0 TDI PD • PDF • 3.3 MB
- Instrukcja obsługi BLS / BXE / BMN – Polish 1.9 / 2.0 TDI PD • PDF • 3.3 MB